EE question paper 2021
Â
Government job alerts and Study materials
Â
In Continuation of Multiple choice Electrical Engineering Solved Questions read the following Questions useful for EE Recruitment Examinations. Answers provided below each questions to store in your memory permanently. There are 15 questions below from Sl. No 11 to 25
EE Question # 11. The number of armature parallel paths in a two-pole D.C. generator having duplex lap
winding is
(a) 2
(b) 4
(c) 6
(d) 8
Ans: b
EE Question #12 . The series field of a short-shunt D.C. generator is excited by
(a) external current
(b) armature current
(c) shunt current
(d) load current
Ans: d
EE Question # 13. Shunt generators are most suited for stable parallel operation because of their
(a) rising voltage characteristics
(b) identical voltage characteristics
(c) drooping voltage characteristics
(d) linear voltage characteristics
Ans: c
EE Question # 14. The main factor which leads to unstable parallel operation of flat and over
compounded generators is
(a) their rising voltage characteristics
(b) unequal number of turns in their series field windings
(c) unequal speed regulation of their primemovers
(d) unequal series field resistances
Ans: b
EE Question # 18. As a result of armature reaction, the reduction in the total mutual air gap flux in a D.C.
generator is approximately
(a) 40 percent
(b) 25 percent
(c) 10 percent
(d) 5 percent
Ans: d
EE Question # 19. On which of the following variables heat convected depends ?
(a) Power density
(b) Temperature difference between heated surface and coolant
(c) Thermal resistivity, density, specific heat
(d) Gravitational constant
(e) All ofthe above
Ans: e
EE Question # 22. For both lap and wave windings, there are as many commutator bars as the number of
(a) slots
(b) armature conductors
(c) winding elements
(d) poles
Ans: c
EE Question # 24. Which generator would you prefer for feeding long D.C. transmission lines ?
(a) Series generator
(b) Shunt generator
(c) Over compound generator
(d) Flat compound generator